Technical data
Rated primary voltage | 230V |
Rated secondary voltage | 12V |
Rated power range | 130VA | 350VA | 700VA |
Protection against electric shock | Class I |
Thermal class | B (130ºC) F (155°C) |
Rated ambient temperature | 40ºC |
Protection index | IP00 | IP20 |
Frequency | 50/60Hz |
Dielectric strength between primary and secondary |
≥4,5kV |
Dielectric strength between windings and metallic parts |
≥2,5kV |
Ambient temperature of service * | -25°C … 70°C |
Storage temperature | -40°C … 85°C |
* For ambient temperatures higher than 40ºC it is necessary to apply a derating. |
Standards
IEC/EN 61558-1 Transformers, general specifications
IEC/EN 61558-2-6 Safety transformers
Constructive characteristics
Electrostatic screen between primary and secondary |
Windings in F(155°C) or H(180°C) thermal class |
Flexible insulation Class B(130ºC) or F(155°C) |
Impregnation with varnish Class F(155°C) |
Casing and mount base in polyamide self extinguishable |
TIG welded magnetic core prevent vibration and allows small air gap to reduce the magnetization current |